Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Indian J Physiol Pharmacol ; 2015 Apr-June ; 59(2): 238-241
Article in English | IMSEAR | ID: sea-158718

ABSTRACT

Measurement of blood pressure is an integral part of clinical examination. Over the years various types of instruments have been used to measure blood pressure but till date the mercury sphygmomanometer is regarded as the gold standard. However, there is a myth prevalent among health professionals regarding the level of the manometer in relation to heart at the time of measuring of blood pressure. Many professionals insist that it has to be placed at the level of the heart. We argue that the limb from which pressure is measured must be at the heart level rather than the manometer. We conducted a study in which we measured the blood pressure in adults by placing the manometer at three different levels with respect to the heart. The values of blood pressure obtained at all levels were similar and did not show any statistically significant difference. We therefore conclude that the level of sphygmomanometer per se does not affect blood pressure measurement.

SELECTION OF CITATIONS
SEARCH DETAIL